Ferrous and Non-ferrous Coating Thickness Gauge TIME®2510 mempunyai dua metode pengukuran ketebalan: induksi magnetik (besi) dan arus eddy (non-besi). Alat ini dapat dengan cepat, tidak merusak, dan secara tepat mengukur ketebalan lapisan non-magnetik pada substrat logam magnetik, dan ketebalan lapisan non-konduktif pada substrat logam non-magnetik. Alat ini secara otomatis mendeteksi jenis logam yang akan diukur. Pengukur ketebalan TIME2510 sangat ideal untuk pengujian permukaan yang dicat, inspeksi cat mobil, pengujian bahan berlapis, dan aplikasi kontrol kualitas.
Features
- Two principle of operation are adopted: magnetic induction (ferrous) and eddy current (nonferrous) to take non-destructive measurements
- Zero point calibration and two-point calibration to correct the system error of the probe
- Features two working modes: DIRECT and BATCH & two measuring ways: CONTINUE and SINGLE
- Statistics include the mean, maximum, minimum, test numbers and standard deviation.
- Automatic recognition of substrate.
- Memory of 600 data
- Deletion of current data, calibrated data, limit data and all data stored.
- Low battery indication and error alarm
- Buzz during operation for indication
- Auto or manual shutdown
Specification
|
Probe types |
F |
N |
|
|
Working principle |
Magnetic induction |
Eddy current |
|
|
Measuring range |
0-1250 μm |
0-1250 μm, 0-40μm (for chrome plate on copper) |
|
|
Minimum resolution |
0.1μm |
||
|
Tolerance |
Zero point calibration |
±(3%H+1) μm |
±(3%H+1) μm |
|
H means the thickness of tested piece |
|||
|
Two points calibration |
±{(1-3)%H+1}μm |
±{(1-3)%H+1}μm |
|
|
H means the thickness of tested piece |
|||
|
Measuring condition |
Min. curvature radius |
Convexity 1.5 mm |
Convexity 3 mm |
|
Min. area diameter |
Φ7 mm |
Φ5 mm |
|
|
Critical thickness of the base |
0.5 mm |
0.3 mm |
|
|
Operating environment |
Temperature: 0℃- 40℃ |
||
|
Humidity: 20%-90% |
|||
|
No strong magnetic field |
|||
|
Power |
2 pcs AAA 1.5 V battery |
||
|
Dimension |
110 x 50 x 23 (mm) |
||
|
Weight |
100 g |
||