HOBO Water Level Data Logger U20L
Jika anda berminat untuk membeli alat HOBO Water Level Data Logger yang disediakan oleh Global Teknik Pasundan, silahkan anda langsung hubungi kami melalui :
PT. Global Teknik Pasundan
Alamat: Jl. Pd. Kelapa Raya No.3B, RT.10/RW.1, Pd. Klp., Kec. Duren Sawit, Kota Jakarta Timur, Daerah Khusus Ibukota Jakarta 13450
Whatsapp : +62 851‑9090‑8341 (Dani)
Email : gtpasundan@gmail.com
Telp : +62 851‑9090‑8341 (Dani)
Request Perminta
Description
Overview
Pencatat data berbiaya rendah dan berkelas penelitian untuk pemantauan terus menerus terhadap ketinggian dan suhu air pada kedalaman hingga 13, 30, atau 100 kaki di berbagai lingkungan bawah air. Pencatat data ini memiliki akurasi pengukuran 0,1%, wadah polipropilena untuk digunakan di air tawar dan air asin, dan desain tanpa ventilasi untuk penggunaan yang nyaman dan tidak merepotkan.
Features
Self-contained, non-vented design enables easy deployment
Ideal for use in both freshwater and saltwater environments, including wells, streams, lakes, wetlands, and tidal areas
Depths up to 13, 30, or 100 feet depending on model
Durable ceramic pressure sensor withstands freezing
HOBOware Pro software provides easy conversion to accurate water level reading, fully compensated for barometric pressure, temperature, and water density
spesifikasi
Pressure (Absolute) and Water Level Measurements U20L-01
- Operation Range
-
0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude
- Factory Calibrated Range
-
69 to 207 kPa, 0° to 40°C10 to 30 psia, 32° to 104°F
- Burst Pressure
-
310 kPa or 18 m depth45 psia or 60 ft depth
- Water Level Accuracy*
-
Typical error: ±0.1% FS, 1.0 cm (0.03 ft) waterMaximum error: ±0.2% FS, 2.0 cm (0.06 ft) water
- Raw Pressure Accuracy**
-
±0.3% FS, 0.62 kPa (0.09 psi) maximum error
- Resolution
-
<0.02 kPa water0.007 ft water
- Pressure Response Time (90%)***
-
<1 second at a stable temperature; measurement accuracy also depends on temperature response time
Pressure (Absolute) and Water Level Measurements U20L-02
- Operation Range
-
0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea level, or 0 to 33.6 m (0 to 111 ft) of water at 3,000 m (10,000 ft) of altitude
- Factory Calibrated Range
-
69 to 400 kPa (10 to 58 psia), 0° to 40°C (32° to 104°F)
- Burst Pressure
-
500 kPa (72.5 psia) or 40.8 m (134 ft) depth
- Water Level Accuracy*
-
Typical error: ±0.1% FS, 3.0 cm (0.1 ft) water Maximum error: ±0.2% FS, 6.0 cm (0.2 ft) water
- Raw Pressure Accuracy**
-
±0.3% FS, 1.20 kPa (0.17 psi) maximum error
- Resolution
-
<0.04 kPa (0.006 psi), 0.41 cm (0.013 ft) water
- Pressure Response Time (90%)***
-
<1 second at a stable temperature; measurement accuracy also depends on temperature response time
Pressure (Absolute) and Water Level Measurements U20L-04
- Operation Range
-
0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m (0 to 23 ft) of water at 3,000 m (10,000 ft) of altitude
- Factory Calibrated Range
-
69 to 145 kPa (10 to 21 psia), 0° to 40°C (32° to 104°F)
- Burst Pressure
-
310 kPa (45 psia) or 18 m (60 ft) depth
- Water Level Accuracy*
-
Typical error: ±0.1% FS, 0.4 cm (0.013 ft) water Maximum error: ±0.2% FS, 0.8 cm (0.026 ft) water
- Raw Pressure Accuracy**
-
±0.3% FS, 0.43 kPa (0.063 psi) maximum error
- Resolution
-
<0.014 kPa (0.002 psi), 0.14 cm (0.005 ft) water
- Pressure Response Time (90%)***
-
<1 second at a stable temperature; measurement accuracy also depends on temperature response time
Temperature Measurements (All Models)
- Operation Range
-
-20° to 50°C-4° to 122°F
- Accuracy
-
±0.44°C from 0° to 50°C , see manual for plot±0.79°F from 32° to 122°F , see manual for plot
- Resolution
-
0.10°C at 25°C , see manual for plot0.18°F at 77°F , see manual for plot
- Response Time (90%)
-
10 minutes in water (typical)
- Stability (Drift)
-
0.1°C per year0.18°F per year
Logger
- Real-time Clock
-
±1 minute per month 0° to 50°C (32° to 122°F)
- Battery
-
2/3 AA, 3.6 Volt lithium, factory-replaceable
- Battery Life (Typical Use)
-
5 years with 1 minute or greater logging interval
- Memory (Non-volatile)
-
64K bytes memory (approx. 21,700 pressure and temperature samples)
- Weight
-
Approximately 154 g (5.43 oz) in airApproximately 53.9 g (1.9 oz) in fresh water
- Dimensions
-
3.18 cm (1.25 inches) diameter, 15.24 cm (6.0 inches) length; mounting hole 6.3 mm (0.25 inches) diameter
- Wetted Materials
-
Polypropylene housing and lanyard; Viton and Buna-N O-rings; ceramic sensor in acetal end cap; stainless steel screws suitable for saltwater
- Logging Interval
-
Fixed-rate or multiple logging intervals, with up to 8 user-defined logging intervals and durations; logging intervals from 1 second to 18 hours. Refer to the HOBOware User’s Guide for details.
- Launch Modes
-
Immediate start and delayed start
- Offload Modes
-
Offload while logging; stop and offload
- Battery Indication
-
Battery voltage can be viewed in status screen and optionally logged in datafile. Low battery indication in datafile.
- Environmental Rating
-
IP68