AZ Instruments 88595 AZ GLP 4 Channel K/J/T/R/S/E Thermocouple Logger

Jika anda berminat untuk membeli alat AZ Instruments 88595 AZ GLP 4 Channel K/J/T/R/S/E Thermocouple Data Logger yang disediakan oleh Global Teknik Pasundan, silahkan anda langsung menghubungi kami melalui :

PT Global Teknik Pasundan

  • Alamat: Jl. Pd. Kelapa Raya No.3B, RT.10/RW.1, Pd. Klp., Kec. Duren Sawit, Kota Jakarta Timur, Daerah Khusus Ibukota Jakarta 13450
  • Whatsapp / Email : Hubungi Kami
  • Telopon atau WA : + 62 895-2811-6846 (Admin)

Category: Brand:

Description

The AZ 88595 4-Ch Thermocouple Logger is developed under high-quality manufacturing processes to ensure reliability and safety:
ISO 9001 Facility: Manufactured in an ISO 9001 certified environment.
CE EN 61326-1 & IEC 61000: Designed and tested to meet European EMC safety standards.
RoHS & REACH Compliant: We provide a Manufacturer’s Self Declaration, ensuring the product meets environmental safety standards for hazardous substances.

88595 AZ GLP 4 Channel K/J/T/R/S/E Thermocouple Data Logger features:
* Designed to meet Good Laboratory Practice (GLP), password access control is included.
* Extra-large LCD with dual-color adjustable backlighting for enhanced visibility
* Multi-cycle start/stop logging functionality and software-free data download to PC
* High/low alarm & temperature offset of each channel is individually programmable 

Application
Application of 88595 AZ GLP 4 Channel K/J/T/R/S/E Type Thermocouple Logger:

The 88595 AZ K/J/T/R/S/E Type Temperature Recorder is suitable for various applications where precise temperature monitoring and data recording are essential. 

1. Laboratory Research and Experimentation
– Why it fits:
The 88595 AZ 4 Channel K/J/T/R/S/E Type Temperature Recorder is designed to meet Good Laboratory Practice (GLP) standards with password access control, ensuring data integrity and security—crucial for controlled experiments in scientific research.

– Use case:
Monitoring temperature in chemical reactions, biological incubations, or material testing, where multiple samples need simultaneous tracking (using the 4 channels). The high/low alarm feature can alert researchers to deviations, and the temperature offset allows calibration for accuracy.

2. Food Safety and Quality Control
– Why it fits:
The ability to log temperature data over time and download it without software simplifies compliance with food safety regulations (e.g., HACCP).

The extra-large LCD with adjustable backlighting ensures readability in various environments, like kitchens or storage areas.

– Use case:
Tracking temperatures in ovens, refrigerators, or during food transport across multiple points. Programmable alarms can signal when food exceeds safe temperature thresholds.

3.Industrial Process Monitoring
– Why it fits:
The multi-cycle start/stop logging functionality is ideal for processes that require periodic temperature checks, and the 4-channel capability supports monitoring multiple zones or equipment simultaneously.

– Use case:
Overseeing temperature in manufacturing processes (e.g., metal forging, plastic molding, or HVAC systems), with alarms set to prevent overheating or equipment failure. Data can be downloaded for quality assurance reports.

4. Pharmaceutical and Medical Storage
– Why it fits:
GLP compliance and secure access make the 88595 AZ 4 Channel K/J/T/R/S/E Type Temperature Recorder suitable for environments requiring strict regulatory oversight. The high/low alarm feature ensures temperature-sensitive materials stay within required ranges.

– Use case:
Monitoring storage conditions for vaccines, drugs, or biological samples in cold chains or incubators, with data logs providing an audit trail for compliance.

5. Environmental Monitoring
– Why it fits:
The 88595 AZ 4 Channel K/J/T/R/S/E Type Temperature Data Logger’s flexibility with programmable offsets and multi-channel logging supports tracking temperature variations across different locations or conditions.

– Use case:
Measuring temperature in climate studies, greenhouses, or server rooms, where maintaining specific ranges is critical. The dual-color backlit LCD enhances visibility in fieldwork settings.

6. Educational and Training Purposes
– Why it fits:
The user-friendly design (software-free data download, clear display) makes it accessible for students or trainees learning about temperature measurement and data logging.

– Use case:
Classroom experiments demonstrating thermodynamics or heat transfer, with the ability to log and analyze data from multiple thermocouples.

The 88595 AZ GLP 4 Channel K/J/T/R/S/E Type Thermocouple Data Logger is well-suited for applications requiring reliable, multi-point temperature monitoring with secure, easy-to-access data recording—spanning research, industry, food safety, pharmaceuticals, environmental studies, and education. 

The 88595 AZ GLP 4 Channel K/J/T/R/S/E Type Thermocouple Data Logger was being designed and manufactured by AZ Instrument, a well experienced manufacturer for Environmental Measuring Instrument.

Specification

Specification of 88595 AZ GLP 4 Channel K/J/T/R/S/E Thermocouple Data Logger:
Model88595
K Temp. Range-200~1370℃, -328~2498℉
J Temp. Range-200~760℃, -328~1400℉
T Temp. Range-200~390℃, -328~730℉
R Temp. Range0~1760℃, 32~3200℉
S Temp. Range0~1760℃, 32~3200℉
E Temp. Range-200~736℃, -328~1356℉
Buzzer~70 dB at 10cm distance
Temp. ResolutionAbove 1000 ℃/℉ is 1 ℃/℉ Below 1000 ℃/℉ is 0.1 ℃/℉
Temp. Accuracy± 0.5℃ for under 1000℃, 1℃ for above ± 0.9℉ for under 1832℉ , 1.8℉ for above
BacklightBlue and Red (red for alarm)
Memory48,000 records for auto logging 99 reocrds for manual logging
Sampling Rate1, 2, 5, 10, 15, 30 sec 1, 2, 5, 10, 15, 30, 60, 90 min
Start Delay0, 1, 5, 10, 30 min 1, 2, 5, and 24 hrs
PowerBuilt-in rechargeable 3.7V Li battery with USB Type C port
Consumption<6.5mA (BLT off); <30mA (BLT on) >120 working hours (BLT/Buzzer off)
LCD Size60(L) * 75(W) mm
Operating Temperature10~60℃
Operating RH%Humidity <80%
Storage Temperature-20~50℃
Storage RH%Humidity <90%
Meter Size180(L) * 75(W) * 50(H) mm
Weight~200g
Standard PackageMeter, Class 1 K bead Thermocouple 4PCS, Manual, Carry case, USB-C cable
Optional AccessoryIR printer, Universal adaptor

FAQ

【FAQ of AZ 88595 GLP 4-Channel Thermocouple Temperature Data Logger】

Q1: What makes the AZ 88595 compliant with GLP standards? A: The AZ 88595 features password access control to ensure data integrity and prevent unauthorized settings changes, meeting strict Good Laboratory Practice (GLP) requirements for secure data management.Q2: How does the dual-color backlight assist in monitoring? A: The extra-large LCD features an adjustable dual-color backlight. It stays blue during normal operation and automatically switches to a red flashing backlight if a temperature alarm is triggered, providing instant visual alerts.Q3: Do I need special software to download recorded data? A: No, the AZ 88595 is designed for efficiency. It supports software-free data download, allowing you to export logs directly to a PC via a USB Type-C cable for quick analysis and reporting.